Abstract: This application note provides the requirements for multiplexing four PCM streams into one 8MHz system backplane using Dallas Semiconductor/Maxim SCTs and framers that do not contain interleave bus operation (IBO) modes internally.The DS2155, DS26528, DS26524, DS26522, DS26521, DS26519 and DS26518 all contain IBO functionality without external circuitry and are recommended for new designs.

Introduction

This application note applies to the following products:

T1 Framers E1 Framers T1 SCTs E1 SCTs
DS2141A DS2143 DS2151 DS2153
DS21Q41B DS21Q43A DS2152 DS2154

This application note will discuss the requirements for multiplexing four PCM streams into one 8MHz system backplane using Dallas Semiconductor SCTs and framers that do not contain interleave bus operation (IBO) functionality internally. The DS2155, DS26528, DS26524, DS26522, DS26521, DS26519 and DS26518 all contain IBO functionality internally and do not need the extra logic shown below.

T1 or E1 PCM signals can interface to an 8MHz system backplane. Typically, this application is used to multiplex four PCM streams onto a single 8MHz PCM stream. To accomplish this, the elastic stores are enabled and placed in the 2.048MHz SYSCLK mode. Figure 1 illustrates a circuit in which a single SYNC signal is generated for all four framers. Each framer in turn is driven with an 8.192MHz clock burst of 8 cycles. Each clock burst causes the elastic store to output one DS0. This results in a byte-interleaved 8.192MHz PCM steam (see Figure 2).

Figures 1 and 2 apply to the DS2152 and DS2154. Figure 1 shows the 8.192MHz clock can optionally be derived from a master DS2152/54.

Figure 1.
Figure 1.

Figure 2.
Figure 2.

Master Clock Source

In Figure 1, the 8.192MHz system clock may be derived from a T1/E1 line as indicated by the dotted line. This line becomes the timing master for the other three devices. In this example, device #1 is used as the master. The other three devices may experience frame slips since there is no guarantee that their inbound T1/E1 rates are synchronous to device #1's inbound rate. The elastic stores manage frame slip events in a logical manner by either repeating or deleting a full frame.

Master Clock Failure

In the event that the master line fails, the following events will occur. RCLK will be replaced by MCLK. If the jitter attenuator is enabled in the receive path, this transition will be very smooth. Consequently, the 8.192MHz clock output on the 8 MCLK pin will make a slight and smooth transition to be phase locked to the clock at MCLK. The 8.192MHz system timing will not experience any disturbance of the byte interleave structure. Device #1 will report a receive carrier loss (RCL) event via the status registers. When the host detects the failure of the master line, processor selection logic may be used to switch to another active line.

Figures 3 and 4 apply to the DS2141, DS21Q41, DS2143, DS21Q43, DS2151, and DS2153.

Figure 3.
Figure 3.

Figure 4.
Figure 4.

Backplane Information

If you have further questions on backplane operation of our legacy T1/E1 products, please contact the Telecommunication Applications support team via email or call 972-371-6555.

For more information about our legacy T1/E1 products, please consult the data sheets available on our website at www.maxim-ic.com/telecom.

関連製品
DS2143 E1コントローラ  
DS2152 強化型T1シングルチップトランシーバ  
DS2154 強化型E1シングルチップトランシーバ  
DS26518 8ポートT1/E1/J1トランシーバ 無料
サンプル
 
DS26519 16ポートT1/E1/J1トランシーバ 無料
サンプル
 
DS26521 シングルT1/E1/J1トランシーバ 無料
サンプル
 
DS26522 デュアルT1/E1/J1トランシーバ 無料
サンプル
 
DS26524 クワッドT1/E1/J1トランシーバ 無料
サンプル
 
DS26528 オクタル(8回路) T1/E1/J1トランシーバ 無料
サンプル
 


次のステップ
EE-Mail EE-Mail配信の登録申し込みをして、興味のある分野の最新ドキュメントに関する自動通知を受け取る。
Download ダウンロード、PDFフォーマット (71kB)  
シェア
その他のチャンネル  E-Mailこのページを知り合いに送る。




フィードバックをお寄せください。
内容に満足されましたか、あるいは満足されていませんか?もっと良いページにできると思いますか?あるいは、単なるコメントでも結構です。フィードバックをお待ちしています。—マキシムはお客様からいただく訂正、提案を元に改善していきます。 このページを評価し、フィードバックを送信する。



APP 301: May 29, 2001
アプリケーションノート301, AN301, AN 301, APP301, Appnote301, Appnote 301

シェア



その他




    |         |         |     プライバシーポリシー     |     法的お知らせ
Copyright © 2012 by Maxim Integrated Products