ユーザーガイド3918

User's Guide for the MAX6877 Power-Supply Tracker/Sequencer

筆者: Eric Schlaepfer, Applications Engineer
Sep 20, 2006

Abstract: This application note is a step-by-step User's Guide for designing with the MAX6877 voltage tracker and sequencer. The note explains how to make suitable component calculations.

Figure 1. The basic circuit for the MAX6877.
Figure 1. The basic circuit for the MAX6877.

MAX6877 Overview

  • Tracks or sequences up to three voltages
  • Closed-loop tracking control with programmable slew rate
  • Program thresholds with resistors
  • Program slew rate and timing delays with capacitors
  • Fault output and power-good output

Description

The MAX6877 voltage tracker/sequencer can track or sequence up to three voltages. Use the TRACK/SEQ pin to select tracking or sequencing. The device will either track or sequence the three voltages, but it cannot track and sequence simultaneously. Power-up begins when EN/active-low UV is asserted and all three input voltages are above their thresholds. In the example circuit in Figure 1, EN/active-low UV is connected to the 12V bus, so the circuit will turn on when the bus exceeds its threshold and turn off when it falls under its threshold.

To create a basic design with the MAX6877, such as the one in Figure 1, follow these steps:
  1. Select the input voltage thresholds for IN1, IN2, and IN3. The input voltages must exceed these thresholds for power-up to begin. Use the following formula to set the resistor-divider values for IN1. (For IN2 or IN3, replace R1 with R3, or R5 and R2 with R4 or R6.)

    Equation 1

  2. Select the EN/active-low UV threshold using the following formula. EN/active-low UV can also be used as a logic-level input to control power up. If not used, connect EN/active-low UV to ABP.

    Equation 2

  3. Set the voltage slew rate. (This is the rate at which the voltages at the outputs OUT1, OUT2, OUT3 ramp up and down.) Select capacitor CSLEW by using the following formula:

    Equation 3

    where CSLEW is in farads, and SR is in V/s. CSLEW must be in the range of 100pF < CSLEW < 1nF.

  4. In sequencing-mode only, the voltages come up one after another, separated by a time delay which is set by capacitor CDELAY using the following formula:

    Equation 4

    where CDELAY is in farads, and tDELAY is in seconds. tDELAY is also the delay time from when all thresholds are exceeded to the start of sequencing or tracking. CDELAY can be safely left out of the circuit, in which case tDELAY becomes the default 200µs.

  5. Pick the MOSFETs for each channel. Ensure that the MAX6877 gate-drive circuit can drive the gate capacitance of the MOSFET.
Multiple MAX6877 parts can be connected together by connecting the power-good output of the first device to the enable input (EN/active-low UV) of the next device. For more information, see the data sheet.



関連製品
MAX6877 デュアル/トリプル電圧、電源トラッカ/シーケンサ/監視回路 無料
サンプル
 


次のステップ
EE-Mail EE-Mail配信の登録申し込みをして、興味のある分野の最新ドキュメントに関する自動通知を受け取る。
Download ダウンロード、PDFフォーマット (39kB)  
シェア
その他のチャンネル  E-Mailこのページを知り合いに送る。




フィードバックをお寄せください。
内容に満足されましたか、あるいは満足されていませんか?もっと良いページにできると思いますか?あるいは、単なるコメントでも結構です。フィードバックをお待ちしています。—マキシムはお客様からいただく訂正、提案を元に改善していきます。 このページを評価し、フィードバックを送信する。



APP 3918: Sep 20, 2006
ユーザーガイド3918, AN3918, AN 3918, APP3918, Appnote3918, Appnote 3918

シェア



その他




    |         |         |     プライバシーポリシー     |     法的お知らせ
Copyright © 2012 by Maxim Integrated Products