| 1.1.1 |
Loss of ground with all switches open |
Current does not change |
Appears to operate |
C0 00 00 00 |
Succeeds |
SDO "low" output voltage is raised to 0.5V. |
| 1.1.2 |
Loss of ground with at least one input connected to chassis ground |
Current does not change |
- |
C0 00 00 00 |
Succeeds |
Switch not reported closed. All output bits 0, apart from DT and Rst. |
| 1.2 |
Loss of power with an input connected to battery voltage |
Current goes to 0 |
- |
00 00 00 00 |
Fails |
|
| 1.3 |
Loss of ground and power with one input grounded |
Current goes to 0 |
- |
00 00 00 00 |
Fails |
|
| 1.4 |
Loss of ground and power with one input connected to battery voltage |
Current goes to 0 |
- |
00 00 00 00 |
Fails |
|
| 1.5 |
Loss of ground and power with one input connected to battery and one input grounded |
Current goes to 0 |
- |
00 00 00 00 |
Fails |
|
| 2.1 |
Reverse-battery with all
switches open |
Current goes to 0 |
Inert |
- |
- |
|
| 2.2 |
Reverse-battery with one input grounded |
Current goes to 0 |
Inert |
- |
- |
|
| 2.3
|
Reverse-battery with
one input connected to
battery |
None |
Inert |
- |
- |
|
| 2.4 |
Reverse-battery with one input connected to ground and one to battery |
Current goes to 0 |
Inert |
00 00 00 00 |
Fails |
Set up with two power supplies so that SPI read was possible. |
| 3.1 |
Negative GND shift at pin 18 |
Current does not change |
Normal operation |
Succeeds |
Succeeds with 5V offset |
Tested with up to 5V offset and with no malfunction. |
| 3.2 |
Positive GND shift at pin 18 |
Current does not change |
Normal operation |
Succeeds |
Succeeds with 5V offset |
At 3.2V did not detect a closed ground-connected switch; it still worked at 3.1V. High-side switch detection still worked with 5V offset. |
| 3.3 |
Positive battery voltage shift on battery-connected switch |
Current does not change |
Normal operation |
Succeeds |
Succeeds with 5V offset |
No malfunction at up to 5V offset. |