DS1921K Thermochron iButton Kit Overview

The DS1921K Thermochron® iButton® Kit introduces users to the temperature logging capabilities of the Thermochron. Using a personal computer, the Thermochron temperature logger can be setup for a temperature gathering mission. After a temperature gathering mission, the data can be downloaded and viewed or exported. Instructions and software are available to download for free from this website.

The starter kit includes one of each of the parts listed below. The DS1921K is also capable of evaluating any sensor iButton, including high-capacity thermochrons (DS1922L and DS1922T), the hygrochron (DS1923), and the temperature-only iButton (DS1920). Please note that only the DS1921 is included in the kit. Other sensor iButtons will need to be purchased separately.

DS1921K List of Contents

iButton
Key Specifications:   iButton Products
Part Number Overview Memory Type Memory Size Data Logger Type Data Logger Size Data Logger Measurement Range Programmable Alarm UniqueWare Real-Time Clock RoHS Available Price**
DS1921G 
Temperature Sensor iButton
NV SRAM 4Kbits Temperature 2048 Byte -40°C to +85°C Temperature High/Low No Yes Yes $14.25 @ 1k
See All iButton Products (25)
Notes:
**This pricing is BUDGETARY, for comparing similar parts. Prices are in U.S. dollars and subject to change. Quantity pricing may vary substantially and international prices may differ due to local duties, taxes, fees, and exchange rates. For volume-specific prices and delivery, please see the price and availability page or contact an authorized distributor.
 
iButton Mount
Key Specifications:   iButton Mounting Options
Part Number Overview Features Price**
DS9093F  DS9093F
Key Fob, Flanged
Black
F3 Package Compatible
F5 Package Compatible
Fobs
Plastic Part
$0.66 @ 1k
See All iButton Mounting Options (29)
Notes:
**This pricing is BUDGETARY, for comparing similar parts. Prices are in U.S. dollars and subject to change. Quantity pricing may vary substantially and international prices may differ due to local duties, taxes, fees, and exchange rates. For volume-specific prices and delivery, please see the price and availability page or contact an authorized distributor.
 
iButton Accessories
Key Specifications:   iButton Readers and Adapters
Part Number Overview Features RoHS Available Price**
DS9490R 
USB to 1-Wire RJ11
USB Port
USB Port Adapters
With ID
Yes $13.75 @ 1k
DS1402D-DR8 
Blue Dot Receptor, USB and Serial Port
Blue Dot
F5 Package Compatible
RS-232 Port Adapter Cables
USB Port Adapter Cables
Yes $4.51 @ 1k
See All iButton Readers and Adapters (25)
Notes:
**This pricing is BUDGETARY, for comparing similar parts. Prices are in U.S. dollars and subject to change. Quantity pricing may vary substantially and international prices may differ due to local duties, taxes, fees, and exchange rates. For volume-specific prices and delivery, please see the price and availability page or contact an authorized distributor.
 

Getting Started

The 1-Wire Drivers (also known as the TMEX Runtime Environment) installation package is available to help evaluate the different versions of iButtons, including the Thermochron. You can download and install the 1-Wire Drivers from here. Detailed instructions on the installation can be found here.

There are several different distributions of the 1-Wire Drivers available. It is highly recommended that you download a distribution that comes with the iButton Viewer and/or the OneWireViewer. These are PC software programs used to evaluate Thermochrons and other iButton/1-Wire products. We also encourage a thorough reading of the on-line documentation available on the 1-Wire Drivers download site before undertaking any experiments. Keep in mind that the iButton Viewer has a help file which will save you time and enhance your first impression of iButtons.

To get started, first install the hardware on a PC. Snap the RJ-11 end of the DS1402D-DR8 Blue Dot Receptor into the RJ-11 port on the DS9490R. The DS9490R is a USB to 1-Wire/iButton adapter. Connect the DS9490R adapter to an unused USB port on your computer. Now, install the 1-Wire Drivers and select the USB port used when prompted.

Snap a Thermochron iButton into the DS9093F fob. Simply slide the iButton into the DS9093F until it snaps into place.

Next execute the iButton Viewer on your PC. The iButton Viewer comes with its own help file and can be accessed by pressing the F1 key at anytime while running the program.

Snap the iButton with fob into the Blue Dot receptor and you will see its address displayed on your PC in the Viewer. Double click on the address to access screens that show all the functions of each iButton. Then, follow the instructions for missioning and reading the contents of a Thermochron.

Troubleshooting Guide

Symptom Possible Cause Corrective Action
Message Figure A or similar Cause 1: The port is in use by another application. Verify that no application has the port open or is sharing an interrupt with the port. Look at modem and synchronization software for hand-held computers.
(Same as above) Cause 2: The PC port hardware is not functioning properly. Does the port work with other applications, such as terminal or mouse? 
(Same as above) Cause 3: The 1-Wire adapter is not functioning. Try 1-Wire adapter on another PC. If the problem persists, use a different 1-Wire adapter or order a new adapter of this type.
(Same as above) Cause 4: Incorrect adapter or PC port selected. The adapter type is not what is connected, or the port number may be incorrect. Try the 'Auto-detect' feature.
Message Figure B See Cause 1 to 3 above. See above.

Errors during Installation or from Default 1-Wire Net:

Figure A
Figure B


Here are some quick links to get you started once you receive your kit.


Software Development Tools and SDKs
 
Product Data Sheets
 
Application Notes
 
FAQs

If you have trouble with this kit, please feel free to contact us here.


      プライバシーポリシー    法的お知らせ

      Copyright © 2008 by Maxim Integrated Products, Dallas Semiconductor